Item:   Digital Display Inclinometer
Article No.:  SP-2
Dimensions:  160*53*21.5mm
Package:  Standard export carton
Weight:  104g
Description:  This is a digital inclination (angle) sensor achievements into applications.

Introduction

The new SP-2 digital display inclinometer (digital display level) which developed by IRIS Company is a digital inclination (angle) sensor achievements into applications. The LCD digital display level inclinometer using new sensor technology to be developed which alternative to the traditional blisters level sensor, capable of connecting digital instrumentation. Adopts the LCD backlight digital display, can be used at night; realize the quantitative measurement of the angle of deviation from the horizontal plane; Digitized, integrated, miniaturized instruments development trends; widely used in road works, mechanical measurement, construction, and many occasions where need to use gravity reference system; The product has a electronic detection and digital display, etc. characteristics, make our building supervising (inspection) industry farewell the angle measurement that followed the Millennium "to see the blisters for angle measurement ”. SP-2 digital inclinometer with small size, the accuracy can be maintained 0.1 degree within ± 60 measuring range, and currently widely used in construction and railway construction and other industries.


Features

●Accuracy:0.1° 

●Repetitive error:0.07°
●Power supply:9V PP3 alkaline battery 

●With number hold function, convenient for record
●Angle data response fast 

●Angel compensation function
●Working temperature -10°~ +45℃ 

●IP54 protection class
●Stand-by time ::up to 700 days
●Measuring display range:±90°(actual measuring range 360°)
●90 secondes auto power-off, 0deg, 90deg, 180deg auto hint function


Applications

●Building operations 

●Vehicle maintenance 

●Road grade
●Machinery installation 

●Pipe installation 

●Industry platform


Specification

Parameters
SP-2
Unit
Measuring range
4*90
°
Measuring accuracy
< 0.1°; operating temperature region error (temperature drift )<0.05°; long time disperse< 0.1°
°
Working temperature
-10°~ +45℃
°/℃
Storage temperature
-20℃--+80℃

Working current
<100
uA
Working humid
<950x
%RH
Display resolution
0.1
°
Repetitive error
<0.07°
°
ZERO temperature drift
0.05 to 0.005%F.S/℃
%F.S/℃
Power
9V PP3 alkaline battery
V
Stand-by time
700 (pls remove the battery if long time no working)
Day
Power consumption
<100
mW
Shell material
ABS Plastic

Dimension
L160*W52.5*H21.5
mm
Weight
104
g